0 ratings
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3 Phase Converter, MY-PS-2, 1 DPS Must Be Used for 1 Motor Only, Input/Output 200-240V, UL Listed

Item #: 80979298

DPS Used for 1HP(0.75kW) 3A Motor, Single to 3 Phase Converter, MY-PS-2, 1 DPS Must Be Used for 1 Motor Only, Input/Output 200-240V, UL Listed

Item #: 80979298
0 ratings Write a review
Out of stock
us Imported from USA store
Our Top Logistics Partners
  • fedex
  • dhl
U-Care Warranty:
None
Select a Plan
fast shipping

Fast
Shipping

free return

Free
Return*

secure packaging

Secure Packaging

100% original products

100% Original Products

pci-dss

PCI DSS Compliance

iso certified

ISO 27001 Certified


paypal payment
visa payment
mastercard payment
american express payment
ptt group payment
turkiye-bankasi payment
garanti bbva payment
akbank payment
yapi kredi payment
denizbank payment
kuveyt turk payment
vakifbank payment
ziraat bankasi payment
teb payment
sekerbank payment
Note: Step Down Voltage Transformer required for using electronics products of US store (110-120). Recommended power converters Buy Now.

Product Details

Shop DPS Used for 1HP(0.75kW) 3A Motor, Single to 3 Phase Converter, MY-PS-2, 1 DPS Must Be Used for 1 Motor Only, Input/Output 200-240V, UL Listed online at a best price in Turkey. 2899806523
  • Before purchasing a DPS, be sure to check that the DPS model is compatible with your motor specifications. 1) DPS must be appropriately selected and used according to the motor specifications. Check the motor’s rated current (A), horsepower (HP), and voltage (V) and select the DPS model. 2) MY-PS-2 model should be used on 200V-240V 1HP 3amps 3-phase motor. If used on a motor with a horsepower lower than 1HP(for example 0.5HP, 0.25HP, 0.125HP motor), the motor may generate heat, make noise, and cause problems with motor operation. 3) DPS must be used for only one motor. One DPS should never be used on multiple motors. 4) DPS can make 200V-240V 3-phase from 200V-240V single-phase. 5) The voltage of the motor must be set to 200V-240V(Delta wiring-Low voltage). 6) The efficiency is around 90% when using a DPS model that meets the motor specifications. 7) The thickness of wires should be suitable for motor rated current. 8) DPS does not operate on 3-phase motor installed with 3-phase brake. 9) DPS creates induced three phases by running a motor. Therefore, three phases can be measured at the DPS output when the motor is running. If the motor is not running, you cannot measure any three phases at the DPS output. 10) If a magnet contactor is connected to the motor and DPS, you must connect two control wires which are from the magnetic contactor to 'U' and 'W' of the DPS output. If the motor does not work even though the power is turned on after connecting the DPS and the motor, please switch the wires positions of “U”, “V”, and “W” for DPS’s output at least 3 times. If the motor operates in reverse rotation and the positions of the 'U' and 'W' wires of the DPS output are swapped, the motor operates in forward rotation 11) If your machine has a magnetic contactor, it must be 220V only. DPS cannot work for a 380V or 440V magnetic contactor. 12) When the motor initially starts and there is not much load on the motor, the current on the 'U' and 'W' phases of the DPS output may become imbalanced. However, when more than 50% load is applied to the motor, the 'U' and 'W' current values are balanced. The 'V' phase is approximately equal to the motor's rated current value. 13) If the current is imbalanced even when the load on the motor is more than 50%, check whether the DPS model settings are correct. DPS has an available model depending on the specifications of each motor. If you use a DPS higher than the motor specifications, the motor may generate heat or noise. Also, please check whether the motor is overloaded. DPS efficiency is around 90%. In general, the three phases supplied by power companies and the three phases produced by DPS are different. This is because DPS converts from single-phase to three-phase. Therefore, please use a motor with an efficiency of 90% or less.
Motor drive typeSingle to 3 Phase Converter
Input voltage200 V
Watts0.75 kW
BrandDPS
Dimensions3.20 x 2.00 x 3.90 in (8.1 x 5.1 x 9.9 cm)
Weight3.9 lb (1.77 kg)
Model nameMY-PS-2

Product Description

Important information

  • Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
  • Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.